TM 1-2840-252-23-3
8-20
CLEAN FLOW PROGRAMMING VALVE
8-20
INITIAL SETUP
Equipment Condition:
Applicable Configurations:
Off Engine Task
All
Flow Programming Valve Removed (Task 8-
Tools:
19)
General Safety Instructions:
Goggles
WARNING
Dry, Compressed Air Source
Dry cleaning solvent (E19) is flammable and toxic.
Materials:
It can irritate skin and cause burns. Use only in
Dry Cleaning Solvent ( E19 )
well-ventilated area, away from heat and open
Gloves (E24)
flame. In case of contact, immediately flush skin
Lint-Free Cloth (E30)
or eyes with water for at least 15 minutes. Get
Personnel Required:
medical attention for eyes.
1. Wear gloves (E24). Clean flow programming valve (1) . Use dry cleaning solvent (E19) and brush.
WARNING
When using compressed air for cleaning, use approved protective equipment for
eyes and face. Do not use more than 30 psig air pressure. Do not direct air
toward yourself or another person. Failure to comply could result in injury to eyes
or skin. In case of injury, get medical attention.
2. Wear goggles. Blow dry flow programming valve (1) , using clean, dry, compressed air.
FOLLOW-ON MAINTENANCE:
Inspect Flow Programming Valve (Task 8-21).
END OF TASK
8-56