TM 1-2840-252-23-2
6-5. INSTALL HYDROMECHANICAL ASSEMBLY (HMA) (Continued)
6-5
5. Install packing (3), nipple (2), and tee (1) in
serviceablehydromechanical assembly (13).
6. Install packing (6) and nipple (5) in serviceable
hydromechanical assembly (13).
7. Install packing (8) and nipple (7) in serviceable
hydromechanical assembly (13).
8. Install packings (11) and (12), reducer (9), and nipple
(10). In serviceable hydromechanical assembly
(13). Use 1-1/8 inch flare, crowfoot attachment.
9. Install seal (14) on serviceable hydromechanical
assembly (13)as follows.
a. Slide seal (14) onto wrenching end of 3/8 inch
deep style socket (15).
GO TO NEXT PAGE
6-19