TM 1-2840-252-23-2
5-19
INITIAL SETUP
Equipment Condition:
Applicable Configurations:
Off Engine Task
All
Tools
General Safety Instructions
WARNING
Materials:
Dry cleaning solvent (E19) is flammable and
Dry Cleaning Solvent (E19)
toxic. It can irritate skin and cause burns.
Gloves (E24)
Use only in well-ventilated area, away from
Lint-Free Cloth (E30)
heat and open flame. In case of contact,
Personnel Required
immediately flush skin or eyes with water for
Aircraft Powerplant Repairer
at least 15 minutes. Get medical attention
for eyes.
References
:
NOTE
Before cleaning starter drive assembly,
check for evidence of oil leakage at seals.
If evidence of leakage is found, have
1
Wear gloves (E24) and clean starter drive assembly
(1) and gearshaft (2) Use dry cleaning solvent (E19)
and brush
2
Remove any remaining solvent with clean, lint free
cloth (E30)
FOLLOW-ON MAINTENANCE
END OF TASK