TM 1-2840-252-23-2
3-7
ASSEMBLE COMBUSTION SECTION AND POWER TURBINE (AVIM)
3-7
(Continued)
Maximum total thickness of shims in
following step shall be 0.045 inch.
Failure to comply will not allow proper
engagement of mounting bolts. Damage
to engine will result
3. Align bolt holes (4) and install shim (5) on combustor
assembly (3).
GO TO NEXT PAGE
3-63