TM 55-2835-208-232-29 CLEAN AND INSPECT PURGE VALVE ASSEMBLY2-29INITIAL SETUPMaterials:Applicable Configurations:Methyl-Ethyl Ketone (MEK) (E9)Lint-Free Cloth (E13)APU 116305-100Tools:Personnel Required:Rubber Gloves68B Airrcraft Powerplant RepairerNSN 8415-00-266-867768B Powerplant InspectorContainerEye ProtectionEquipment Condition:Off APU TaskMEK (E9) is flammable andtoxic.It can irritateskin and cause burns.Use only in well-ventilatedarea, away from heat andopen flame. Wear glovesand eye protection. Incase of contact, immediatelyflush skin or eyes withwater for at least 15minutes.Getmedicalattentionforeyes.1.Soak purgevalveassemblyinMEK (E9) for 5minutes.2.Remove from MEK and dry withclean lint-free cloth (E13).3.Inspectthreadfittings(1)forcrossed orstrippedthreads.If damaged, discard.4.Inspectpurge valve body(2)for cracks or gouges.If dam-aged, discard.GO TO NEXT PAGE2-58