TM 55-2840-254-23
8-73
8-73 CLEAN STARTER GEARBOX FILTER
INITIAL SETUP
Equipment Condition:
Off Engine Task
Applicable Configurations:
All
General Safety Instructions:
Tools:
Goggles
Compressed Air Source
Dry cleaning solvent (E17) is flam-
mable and toxic. It can irritate skin
Materials:
Dry Cleaning Solvent (E17)
and cause burns. Use only in well-
Gloves (E20)
ventilated area, away from heat and
Lint-Free Cloth (E26)
open flame. In case of contact, im-
mediately flush skin or eyes with
Personnel Required:
water for at least 15 minutes. Get
medical attention for eyes.
1. Clean starter gearbox filter (1) as follows:
a Wear gloves (E20). Immerse filter in dry clean-
ing solvent (E17) and agitate. Use brush on ex-
ternal surfaces (2).
b. Use lint-free cloth (E26) to remove solvent.
When using compressed air for cleaning,
use approved protective equipment for
eyes and face. Do not use more than
30 psig air Pressure. Do not direct air
toward yourself or another person.
Failure to comply could result in injury
to eyes or skin. In case of injury, get
medical attention.
c. Wear goggles. Blow dry internal passage (3).
Use clean, dry compressed air.
FOLLOW-ON MAINTENANCE:
END OF TASK