8-30
8-30 CLEAN DUAL CHIP DETECTOR
INITIAL SETUP
General Safety Instructions:
Applicable Configurations:
All
Dry cleaning solvent (E17) is flammable
Tools:
and toxic. It can irritate skin and cause
burns. Use only in wall-ventilated area,
Goggles
away from heat and open flame. In case
Compressed Air Source
of contact, immediately flush skin or
eyes with water for at least 15 minutes.
Materials:
Get medical attention for eyes.
Dry Cleaning Solvent (E17)
Gloves (E20)
Lint-Free Cloth (E26)
Personnel Required:
Equipment Condition:
Off Engine Task
1. Wear gloves (E20). Clean housing (1) and two
filters (2). Use dry cleaning solvent (E17) and
brush.
When using compressed air for cleaning,
use approved protective equipment for
eyes and face. Do not use more than
30 psig air pressure. Do not direct air
toward yourself or another person.
Failure to comply could result in in-
jury to eyes or skin. In case of injury,
get medical attention.
2. Wear goggles. Blow dry housing (1) and filters
(2), using clean, dry compressed air.
GO TO NEXT PAGE