1107 TEST ENGINE (AVIM) (Continued)
1107
NOTE
In following step, do not exceed water brake temperature limits.
i.
Retard N2 master hydronic control to minimum governing postion; then adjust water in master
hydronic control to obtain 1185 to 1215 phr; N2 speed should not exceed limit given below. Adjust
minimum N2 lever stop as required.
CAUTION
For fuel controls 216162064 and 216162068 the minimum
speed adjustment pointer shall indicate a reading of 13 degrees
to 17 degrees. For fuel controls other than 216162064 and
216162068 the minimum speed adjustment pointer shall not
indicate less than 10 degrees. Malfunction of fuel control may
result.
Overspeed Governor Limits