TM 55-2840-254-23
1-104
1-104 SERVICE INTERSTAGE AIR-BLEED ACTUATOR STRAINER (Continued)
9. Inspect spring (6). There shall be no broken
coils.
10. Install spring (6) in housing (7), large end in.
11. install strainer element (5) in housing (7), open
end out.
GO TO NEXT PAGE
1-438