TM 55-2840-254-23
1-104 SERVICE INTERSTAGE AIR-BLEED ACTUATOR STRAINER (Continued)
1-104
Dry cleaning solvent (E17) is flammable
and toxic. It can irritate skin and cause
burns. Use only in well-ventilated area,
away from heat and open flame. In case
of contact, immediately flush skin or
eyes with water for at least 15 minutes.
Get medical attention for eyes.
6. Wear gloves (E20). Clean strainer element (5)
and spring (6). Use dry cleaning solvent (E17).
When using compressed air for cleaning,
use approved protective equipment for
eyes and face. Do not use more than
30 psig air pressure. Do not direct air
toward yourself or another person, Fail-
ure to comply could result in injury to
eyes or skin. In case of injury, get medi-
cal attention.
7. Wear goggles. Blow dry strainer element (5) and
spring (6) using clean, dry compressed air.
8. Inspect strainer element (5). There shalI be no
tears, punctures, or broken wires in screen.
GO TO NEXT PAGE
1-437