1-101 SERVICE FUEL CONTROL FILTER AND AIR-BLEED POPPET VALVE (Continued)
Do not spray corrosion preventative com-
pound (E14) into air-bleed actuator hose
fitting. Failure to comply, may cause
damage to the actuator.
e. Clean hose assembly (17). Spray corrosion
preventive compound (E14) into both ends
of hose assembly (17).
f. Allow corrosion preventive compound (E14)
to soak for 10 minutes.
g. Wear goggles and gloves (E20). Blow dry hose
assembly (17) using clean, dry compressed
air.
Be sure to lift actuating Iever carefully and
evenly. Spring could be easily stretched.
This would result in air leakage and en-
gine low power.
h. Unseat poppet valve (16) by gently lifting ac-
tuating lever (20) at spring end. Lift actuat-
ing lever (20) off seat (21 ) 0.250 inch.
i. Blow dry poppet valve air passage (22) using
clean, dry compressed air.
GO TO NEXT PAGE