TM 55-2840-254-23
1-101
1-101 SERVICE FUEL CONTROL FILTER AND AIR-BLEED POPPET VALVE (Continued)
Corrosion preventive compound (E14) is
flammable and toxic. Use only in well-
ventilated area away from heat, sparks
and open flames. If swallowed do not in-
duce vomiting. Get medical attention. In
case of contact immediately flush skin
and eyes with water for 15 minutes.
Get medical attention for eyes.
c. Clean poppet valve air passage (22). Spray
corrosion preventive compound (E14)
through air passage hole (22) in fitting (23).
d. Clean poppet valve (16). Spray corrosion
preventive compound (E14) through opening
in shield (24). Release poppet valve (16).
GO TO NEXT PAGE
1-422