1-101 SERVICE FUEL CONTROL FILTER AND AIR-BLEED POPPET VALVE
Reference:
INITIAL SETUP
TM 55-2840-254-23P
Applicable Configurations:
General Safety Instructions:
All
Tools:
Powerplant Mechanic's Tool Kit,
Technical inspection Tool Kit,
Turbine fuels are very flammable. They
may cause drying and irritation of skin or
Goggles
eyes. Handle only in well-ventilated areas
Compressed Air Source
away from heat and open flame. Drain and
store in approved metal safety containers.
Materials:
Avoid prolonged or repeated contact with
Corrosion Preventive Compound (E14)
skin and do not take internally. Wash con-
Dry Cleaning Solvent (E17)
tacted area of skin thoroughly after hand-
Gloves (E20)
ling. If irritation of skin results, get medi-
Lockwire (E29)
cal attention. Get medical attention for
Wiping Rag (E58)
eyes.
Parts:
Packings
Personnel Required:
use approved protective equipment for
eyes and face. Do not use more than 30
psig air pressure. Do not direct air toward
yourself or another person. Failure to
comply could result in injury to eyes or
skin. In case of injury, get medical atten-
tion.
GO TO NEXT PAGE
(1-413 blank/1-414