1-99 SERVICE OIL FILTER CAP AND STEM ASSEMBLY AND OIL FILTER
1-99
ELEMENT (Continued)
6. Clean oil filter cap and stem assembly (1) as
follows:
Dry cleaning solvent (E17) is flammable
and toxic. It can irritate skin and cause
burns. Use only in well-ventilated area,
away from heat and open flame. In case
of contact, immediately flush skin or
eyes with water for at least 15 minutes.
Get medical attention for eyes.
a. Wear gloves (E20). Immerse and agitate cap
and stem assembly (1) in dry cleaning solv-
ent (E17). Use brush on outside surfaces.
b. Wipe outside surfaces dry with clean, dry,
lint-free cloth (E26).
When using compressed air for cleaning,
use approved protective equipment for
eyes and face. Do not use more than 30
psig air pressure. Do not direct air toward
yourself or another person. Failure to com-
ply could result in injury to eyes or skin.
In case of injury, get medical attention.
c. Wear goggles. Blow dry internal passages (5)
using clean, dry compressed air.
stem assembly (1).