TM 55-2835-208-23
2-102 CLEAN AND INSPECT DRIVE SYSTEM
2-102
INITAL SETUP
Applicable Configurations:
Al 1
Tools :
Engine Repairmans Tool Kit
NSN 5180-00-323-4944
Rubber Gloves
NSN 8415-00-266-8677
Container
Eye Protection
Materials:
Dry-Cleaning Solvent (E20)
Lint-Free Cloth (E13)
Personnel Required:
68B Aircraft Powerplant Repairer
68B Powerplant Inspector
Equipment Condition:
Remove Drive System ( T a s k 2 - 1 0 7)
Dry-cleaning solvent (E20)
is flammable and toxic.
It can irritate skin and
cause burns.
Use only
in well-ventilated area,
away from heat and open
flame.
Wear gloves and
eye protection. In
case of contact, immediately
flush eyes or skin with
water for at least 15
minutes.
Get medic=
attention for eyes.
GO TO NEXT PAGE
2-185