TM 55-2835-208-23
2-96 CLEAN AND INSPECT MAGNETIC DRAIN PLUG AND VALVE
2-96
INITIAL SETUP
Materials Required:
Applicable Configurations:
Dry-Cleaning Solvent (E20)
Lint-Free Cloth (E13)
Al1
Personnel Required:
Tools:
68B Aircraft Powerplant Repairer
Engine Repairmans Tool Kit
68B Powerplant Inspector
NSN 5180-00-323-4944
Rubber Gloves
Equipment Condition:
NSN 8415-00-266-8677
Container
Off APU Task
Eye Protection
1.
Inspect magnetic plug
(1) for
metal
particles
(paragraph
1-30) .
=
Dry-cleaning solvent (E20)
is flammable and toxic.
It can irritate skin and
cause burns. Use only in
well-ventilated area, away
from heat and open flame.
Wear gloves and eye pro-
tection.
In case of
contact, immediately flush
eyes or skin with water for
at least 15 minutes. Get
medical attention for eyes.
2.
Wearing gloves and eye protec-
tion,
wipe magnetic
plug (1)
and valve (2) with clean cloth
(E13) dampened with dry-clean-
ing solvent (E20).
3. Wipe dry with clean dry cloth
(E13).
GO TO NEXT PAGE
2-174