TM 55-2835-208-23
2-41 CLEAN AND INSPECT COMPRESSOR FITTING ASSEMBLY
2-41
INITIAL SETUP
M a t e r i a l s :
Applicable Configurations:
Methyl-Ethyl Ketone (MEK) (E9)
Lint-Free Cloth (E13)
AU except APU 116305-100
Tools:
Personnel Required:
Rubber Gloves
68B Aircraft Powerplant Repairer
NSN 8415-00-266-8677
68B Powerplant Inspector
Container
Eye Protection
Equipment Condition:
Off APU Task
1.
2.
3 .
MEK (E9) is flammable and
t o x i c . I t c a n i r r i t a te
skin and cause burns.
Use only in well-ventilated
area, away from heat and
open flame. Wear gloves
a n d e y e p r o t e c t i o n . I n
case of contact, immediately
flush skin or eyes with
water for at least 1 5
minutes.
Get medical
a t t e n t i o n f o r e y e s.
Soak compressor fitting
(E9) for 5 minutes.
in MEK
Remove from MEK and dry with
c l e a n l i n t - f r e e c l o t h ( E 1 3 ).
I n s p e ct
t h r e ad
f i t t i n g s ( 1 )
f or
crossed
o r
s t r i p p ed
t h r e a d s.
If damaged, discard.
GO TO NEXT PAGE
Change 5
2-79