Table 4-3.
Organizational Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
30. OIL SMOKE COMING FROM EXHAUST DURING OPERATION.
NOTE
It is not abnormal to occasion-
ally see
smoke come from the
exhaust
during
startup
and
shutdown.
This
malfunction
refers to
steady
oi1
smoke
appearing during operation.
Step 1.
Check oil level.
If normal or low, go to Step 2.
If high, drain to correct operating level (paragraph 4-8).
Step 2.
Check for oil leaks throughout lubrication system and where
gearbox mates with compressor inlet housing.
If no leaks, go to Step 3.
Repair leaks as necessary.
Step 3.
Inspect exhaust duct for oil streaks.
If streaks present, refer engine to depot level for
inspection and maintenance.
31.