Table 4-2. Troubleshooting-Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
19. HOT WATER EXCESSIVELY HOT TURNED TO
STEAM.
Step 1.
Check exhaust gas flow control valve.
Replace flow valve. (fig. 4-29)
Step 2.
Check hot water temperature switch (S12)
Replace temperature switch. (fig. 4-26)
20.
VENTILATING AIR SYSTEM WILL NOT START.
Step 1.
Check for 400 Hz power.
Refer to figure 2-14 for operation to deliver
400 Hz power. Replace failed components as
required.
Step 2.
Check recirculating fan circuit breakers (CB15
and CB16).
Reset circuit breakers. Replace circuit
breakers as required. (fig. 4-22)
Step 3.
Check vent system select switch (S14)
Replace switch (S14). (fig. 4-21)
Step 4.
Check mode select switch (S16).
Replace switch (S16). (fig. 4-21)
Step 5.
Check recirculating fan contactors (K25) or
(K26).
Replace contactors as required.
Step 6.
Check diode (CR12).
Replace diode (CR12).
21. HEATED AIR SYSTEM WILL NOT DELIVER
HEATED AIR.
Step 1.
Check for 400 Hz power.
Refer to figure 2-14 for operation to deliver
400 Hz power.
Step 2.
Check recirculating fan circuit breaker (CB15) or
(CB16).
Reset circuit brewers. Replace circuit
breakers as required. (fig. 4-22)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 3.
Check heat system select switch (S31).
Replace switch (S31). (fig. 4-21)
Step 4.
Check mode selector switch (S16).
Replace switch (S16). (fig. 4-21)
Step 5.
Check load control valve.
Replace load control valve. (fig. 4-28)
Step 6.
Check air pressure regulator.
Replace air pressure regulator. (fig. 4-28)
Step 7.
Check load control thermostat adjustment.
Refer to paragraph 4-14e(1) for proper adjustment
procedure. Replace thermostat.
(fig. 4-28)
Step 8.
Check heat temperature sensors (RT1, RT2, RT5, RT6).
Replace temperature sensor as required. (fig.1-7)
Step 9.
Check heat system flow control valve.
Replace flow control valve. (fig. 4-29)
Step 10. Check overtemperature thermoswitch (TS5) or (TS9).
Replace thermoswitch as required. (fig. 1-7)
Step 11. Check diode (CR15) or (CR16).
Replace diode as required.
Step 12. Check to see if jumper plug (J93) is installed.
Install or replace jumper plug as required.
22. COOLED AIR SYSTEM WILL NOT DELIVER
COOLED
AIR.
(Refer also to malfunctions listed under item 20)
Step 1.
Check sight glass.
If refrigerant is low, refer problem to direct and
general support maintenance.
Step 2.
Check solenoid valves, pressure controls and lines.
Refer
problem
to
direct
and
general
support
maintenance.
Step 3.
Check compressor time delay and reset relay (K17) or
(K18).
Replace relay as required. (fig. 4 22)
4-24