TM 1-2840-252-23-3
G-70 F/R LAMP
DOES
NOT
ILLUMINATE
WHEN
REVERSION
IS
SELECTED
EXPANDED
INSTRUCTIONS
Step 3.
Check harness connector PL3 (figure 201) at DECU for tight connection.
Step 4.
Disconnect connector PL3 to check pins and sockets.
Step 5.
With PL1 and PL3 disconnected, turn on power to caution panel.
Step 6.
Before tightening harness connector PL3, be sure that keyway in harness connector is aligned
with keyway in DECU connector.
Step 9.
Refer to manufacturer's procedure for diagnosing and replacing F/R lamp.
Step 11.
Refer to manufacturer's procedure for diagnosing and replacing harness.
Step 14.
Refer to manufacturer's procedure for diagnosing and replacing harness or caution panel.
G-166