TM 1-2840-252-23-3
9-5
INSTALL TORQUEMETER SENSOR (Continued)
9-5
Torquemeter sensor Is spring-loaded into housing and must be installed squarely and evenly. Failure to
do so could result in damage to sensor.
NOTE
Do not lockwire over data plate.
3. Install torquemeter sensor (4), four screws (6), data plate (7), and two washers (8). Stagger-tighten and lockwire
screws (6). Use lockwire (E33).
4. Connect electrical connector (9) to torquemeter sensor (4).
GO TO NEXT PAGE
9-11