TM 1-2840-252-23-3
8-110
CLEAN CHIP DETECTOR
8-110
INITIAL SETUP
General Safety Instructions:
Applicable Configurations:
WARNING
All
Dry cleaning solvent (E19) is flammable
Tools:
and toxic. It can irritate skin and cause
burns. Use only in well-ventilated area,
away from heat and open flame. In case
Goggles
of contact, immediately flush skin or
Dry, Compressed Air Source
eyes with water for at least 15 minutes.
Materials:
Get medical attention for eyes.
Dry Cleaning Solvent (E19)
WARNING
Gloves (E24)
When using compressed air for clean-
Lint-Free Cloth (E30)
ing, use approved protective equipment
Personnel Required:
for eyes and face. Do not use more than
30 psig air pressure. Do not direct air
Equipment Condition:
toward yourself or another person. Fail-
Off Engine Task
Engine Oil System Drained (Task 1-69)
ure to comply could result in injury to
Chip Detector Removed (Task 8-109)
eys or skin. In case of injury, get medi-
cal attention.
1. Clean plug (1) as follows:
a. Wear gloves (E24). Clean plug (1) with dry cleaning solvent (E19) and agitate. Use brush on external surfaces.
b. Use lint-free cloth (E30) to remove solvent.
c. Wear goggles. Blow dry plug. Use clean, dry, compressed air.
2. Clean housing (2) as follows:
a. Immerse in dry cleaning solvent (E19) and agitate. Use brush on external surfaces.
b. Use lint-free cloth (E30) to remove solvent.
c. Wear goggles. Blow dry internal passage. Use clean, dry, compressed air.
FOLLOW-ON MAINTENANCE:
Inspect Chip Detector (Task 8-111).
END OF TASK
8-276