TM 1-2840-252-23-3
7-20
TEST PRIMARY ELECTRICAL HARNESS ASSEMBLY
7-20
INITIAL SETUP
Materials:
Applicable Configurations:
None
All
Personnel Required:
Tools:
s
Multimeter
a. Set multimeter range switch to R x 1.
b. Touch red probe (2) to electrical connector (3), sleeve A (4).
c.
Touch black probe (5) to electrical connector (6), pin W (7).
d. Meter shall indicate zero ohms.
f.
Touch black probe (5) to all other pins on electrical connector (6).
g. Meter shall indicate 1000 ohms minimum.
GO TO NEXT PAGE
7-90