TM 1-2840-252-23-3
7-3
INSPECT IGNITION COIL AND CABLE ASSEMBLY (Continued)
7-3
2. Measure insulation resistance on ignition coil and
cable assembly (1) as follows:
red probe (6) to electrical connector conductor (7).
b. Touch black probe (8) to electrical connector outer
housing (9).
c.
Meter shall indicate 1000 ohms minimum.
d. Touch red probe (6) to electrical connector
conductor (7).
e. Touch black probe (8) to electrical connector outer
housing (10).
f.
Meter shall indicate 1000 ohms minimum.
GO TO NEXT PAGE
7-29