TM 1-2840-252-23-2
SECTION II
HYDROMECHANICAL ASSEMBLY (HMA) - PREPARATION FOR STORAGE
OR SHIPMENT
6-6
General Safety Instructions:
INITIAL SETUP
Applicable Configurations:
WARNING
All
Tools:
Lubricating oils cause paralysis if
swallowed. Prolonged contact with them
may irritate the skin Handle only in well-
Hose Assembly (Appendix E) (2)
ventilated areas away from heat and flame
Socket Wrench Handle
Drain and store in approved metal safety
Container, 2 Gallon (2)
containers. Avoid prolonged or repeated
Materials
contact with skin and do not take internally.
High Pressure Caps
Wash contacted area of skin thoroughly
Gloves (E24)
after handling If irritation of skin results, get
Lubricating Oil (E35)
medical attention. Get medical attention for
Personnel Required
eyes.
Equipment Condition
Off Engine Task
NOTE
If hydromechanical assembly is removed
from engine and is not to be reinstalled for
a period longer than 48 hours, it must be
preserved.
1. Install high pressure cap (1) n fitting (2).
o
GO TO NEXT PAGE