TM 1-2840-252-23-2
4-58
REMOVE SECOND TURBINE NOZZLE, SPACER, CASE, AND BUMPER
4-58
(AVIM) (Continued)
6. Remove GP spacer puller(16) from second turbine
spacer as follows:
a. Loosen two 0.625 inch long socket head cap
screws (18) and remove GP spacer puller (16)
from second turbine spacer (7).
b. Remove two 0.625 inch long socket head cap
screws (18) and two puller shells (17) from GP
spacer puller (16).
c. Turn T-handle (10) clockwise all the way.
d. Remove spring pin (14) from adapter (12).
e. Remove adapter (12) from shaft (13), and ball (11)
from base of adapter (12).
GO TO NEXT PAGE
4-318