TM 1-2840-252-23-2
CLEAN FIRESHIELD ASSEMBLY
4-13
INITIAL SETUP
Materials:
Gloves (E24)
Denatured Alcohol (E17)
Applicable Configurations:
All
Personnel Required:
Tools:
Equipment Condition:
NSN 51 80-00-323-4944
Off Engine Task
Goggles
Left- and Right-Hand Bus Bar Assemblies Re-
Dry, Compressed Air Source
1. Wear gloves (E24). Clean fireshield assembly (1)
using denatured alcohol (E17) and brush.
WARNING
When using compressed air for cleaning,
use approved protective equipment for
eyes and face Do not use more than 30
psig air pressure. Do not direct air
toward yourself or another person.
Failure to comply could result in injury
to eyes or skin. In case of injury, get
medical attention.
2. Wear goggles Blow dry fireshield assembly (1) using
clean, dry, compressed air.
FOLLOW-ON MAINTENANCE
END OF TASK