TM 1-2840-252-23-2
2-80
CLEAN CHECK VALVE (WATER WASH TEE TO INTERSTAGE AIR
2-80
BLEED ACTUATOR PM INLET)
INITIAL SETUP
Check Valve (Water Wash Tee to Interstage Air
Applicable Configurations-
All
General Safety Instructions:
WARNING
Tools:
Dry cleaning solvent (E19) is flammable
Goggles
and toxic. It can irritate skin and cause
burns. Use only in well-ventilated area,
Materials:
Dry Cleaning Solvent (El19)
away from heat and open flame. In case
Gloves (E24)
of contact, immediately flush skin or
Lint-Free Cloth (E30)
eyes with water for at least 15 minutes.
Get medical attention for eyes.
Personnel Required:
Equipment Condition:
Off Engine Task
1 Clean check valve (1)as follows
a.
Wear gloves (E24) Immerse valve in dry cleaning
solvent (El9) and agitate. Use brush on external
surfaces.
b.
Use lint-free cloth (E30) to remove solvent
FOLLOW-ON MAINTENANCE
None
END OF TASK
2-423