TM 1-2840-252-23-2
2-77 CLEAN CHECK VALVE (WATERWASH TEE TO INTERSTAGE AIR
2-77
BLEED ACTUATOR P3 INLET)
INITIAL SETUP
Check Valve (Water Wash Tee to Interstage Air
Applicable Configurations
:
All
General Safety Instructions:
Tools:
WARNING
Dry cleaning solvent (E19) is flammable
and toxic. It can irritate skin and cause
burns. Use only in well-ventilated area,
Materials:
away from heat and open flame. In case
Dry Cleaning Solvent (E19)
of contact, immediately flush skin or
Gloves (E24)
eyes with water for at least 5 minutes
1
.
Lint-Free Cloth (E30)
Get medical attention for eyes.
Personnel Required:
Equipment Condition:
Off Engine Task
1. Clean check valve (1)as follows
a. Wear gloves (E24) Immerse in dry cleaning solvent (E19) and agitate Use brush on external surfaces
b. Use lint-free cloth (E30) to remove solvent
FOLLOW-ON MAINTENANCE
None
END OF TASK
2-418