TM 1-2840-252-23-2
2-43 INSTALL OUTPUT SHAFT SEAL AND HOUSING ASSEMBLY (Continued) 2-43
9. Install six bolts (15). Do not lockwire bolts at this time.
INSPECT
10 Check and set output shaft end play as follows
a Push output shaft (1) rearward, and measure depth
from shaft end (16) to seal housing edge (17) using
b Pull output shaft (1) forward and repeat measure-
ment in step a
c Subtract dimension in step b from dimension in step
a Depth of end play shall be between 0.060-0.070
inch.
d If end play is not within limits, proceed as follows
(1) Remove output shaft seal and housing assembly
(2) Repeat steps 2 through 10
e If output shaft end play is still not within limits,
proceed as follows-
(1) Remove output shaft (Ref Contractor Logistic
Support)
(2) Install output shaft (Ref Contractor Logistic
Support)
11. Lockwire six bolts (15) Use lockwire (E33)
INSPECT
FOLLOW-ON MAINTENANCE
Service Engine Oil System (Task 1-68)
END OF TASK
2-344