TM 1-2840-252-23-2
2-42
REPAIR OUTPUT SHAFT SEAL AND HOUSING ASSEMBLY (Continued)
2-42
e. Inspect housing (5). There shall be no cracks The
16 air-bleed holes (10) shall not be clogged.
f.
Install two packings (8) in housing (5).
GO TO NEXT PAGE