TB 9-6625-2182-35
b. Adjustments
NOTE
Turn adjustment screw next to test points listed in table 24.
Adjust to read V dc
Test point
(R)
(HI INPUT)
Adjustments
Min
Max
A17TP1
A17R18
+14.85
+15.15
A17TP2
A17R36
-14.85
-15.15
A17TP3
A17R53
+5.148
+5.252
A17TP4
A17R66
-5.148
-5.252
A17TP5
A17R76
+49.50
+50.50
a. Deenergize and disconnect all equipment.
b. Annotate and affix DA label/form in accordance with TB 750-25.
19/20(Blank)