TM 55-2835-208-232-53 CLEAN AND INSPECT ACCELERATION CONTROL UNIT2-53INITIAL SETUPM a t e r i a l s:Applicable Configurations:Dry-Cleaning Solvent (E20)Lint-Free Cloth (E13)A l lPersonnel Required:Tools:Engine Repairman’s Tool KitNSN 5180-00-323-4944Rubber GlovesNSN 8415-00-266-8677ContainerEye Protection68B Aircraft Powerplant Repairer68B Powerplant InspectorEquipment Condition:Off APU TaskDisassemble Fuel Control (Task 2-52)Dry-cleaning solvent (E20)is flammable and toxic.I t c a n i r r i t a t e s k i n a n dcause burns. Use onlyi n w e l l - v e n t i l a t e d a r e a,away from heat and openflame. Wear gloves and eyep r o t e c t i o n.In case ofcontact, immediately flusheyes or skin with waterfor at least 15minutes.Get medical attention foreyes.1 . U s i n g g l o v e s a n d e y e p r o t e c-t i o n ,wipee x t e r n als u r f a c esw i thl i n t - f r eec l o t h(E13)moistenedw i thdry-cleaningsolvent (E20).2.D r y w i t h c l e a n l i n t - f r e e c l o th(E13).GO TO NEXT PAGE2-101