TM 55-2835-208-232-41 CLEAN AND INSPECT COMPRESSOR FITTING ASSEMBLY2-41INITIAL SETUPM a t e r i a l s :Applicable Configurations:Methyl-Ethyl Ketone (MEK) (E9)Lint-Free Cloth (E13)AU except APU 116305-100Tools:Personnel Required:Rubber Gloves68B Aircraft Powerplant RepairerNSN 8415-00-266-867768B Powerplant InspectorContainerEye ProtectionEquipment Condition:Off APU Task1.2.3 .MEK (E9) is flammable andt o x i c . I t c a n i r r i t a teskin and cause burns.Use only in well-ventilatedarea, away from heat andopen flame. Wear glovesa n d e y e p r o t e c t i o n . I ncase of contact, immediatelyflush skin or eyes withwater for at least 1 5minutes.Getmedicala t t e n t i o n f o r e y e s.Soakcompressorfitting(E9) for 5minutes.in MEKRemove from MEK and dry withc l e a n l i n t - f r e e c l o t h ( E 1 3 ).I n s p e ctt h r e adf i t t i n g s ( 1 )f orcrossedo rs t r i p p edt h r e a d s.If damaged, discard.GO TO NEXT PAGEChange 52-79