1-86 INSPECT CONTAMINATED OIL SYSTEM (Continued)
1-86
1. Remove cable tie (1) and lower free end (2) of
hose assembly (3).
NOTE
For servicing accessory gearbox chip
detector, go to step 13.
NOTE
For servicing dual chip detector, go to
step 14.
2. Remove cap (4).
NOTE
In following step, oil sample shall be
taken within 10 minutes of engine shut-
down.
3. Turn oil drain cock (5) 1/4 turn counterclock-
wise to open position. Allow a minimum of 1
quart of oil to drain from hose assembly (3)
into utility pail.
4. Fill oil sample bottle and install cap.
5. Turn oil drain cock (5) 1/4 turn clockwise to
closed position.
GO TO NEXT PAGE
1-266