TM 1-2840-252-23-2
2-42
REPAIR OUTPUT SHAFT SEAL AND HOUSING ASSEMBLY (Continued)
2-42
Remove retaining ring (1).
I.
m. Install shim (2) and retaining ring (1)
n. Check gap between shim (2) and retaining ring
(1) Gap shall not be more than 0.003 inch
INSPECT
FOLLOW-ON MAINTENANCE
None
END OF TASK
2-337