TM 55-2835-208-23
2-48 CLEAN AND INSPECT FUEL DRAIN CHECK VALVE ASSEMBLY
2-48
INITIAL SETUP
Applicable Configurations:
A l l
Tools:
Engine Repairmans Tool Kit
NSN 5180-00-323-4944
Rubber Gloves
NSN 8415-00-266-8677
Container
Source of Low Pressure Compressed
A i r
Eye Protection
M a t e r i a l s :
Dry-Cleaning Solvent (E20)
Personnel Required:
68B Aircraft Powerplant Repairer
68B Powerplant Inspector
Equipment Condition:
Off APU Task
Dry-cleaning solvent (E20)
is flammable and toxic.
I t c a n i r r i t a t e s k i n a nd
cause burns. Use only in
well-ventilated area away
from heat and open flame.
Wear gloves and eye
p r o t e c t i o n . I n c a s e of
contact, immediately flush
skin or eyes with water
for at least 15 minutes.
Get medical attention for
eyes.
1.
Wearing gloves, flush fuel
drain check valve assembly
with dry-cleaning solvent
(E20).
GO TO NEXT PAGE
2-90