TM 55-2840-254-23
8-102
8-102 ADJUST OIL LEVEL INDICATOR (Continued)
7. Turn switch (8) off and disconnect test light
(T11) (6) from electrical connector (7).
8. Install two spacers (5), cover (4), two washers
(3), and two bolts (2). Torque two bolts (2) to
15 inch-pounds. Lockwire two bolts (2). Use
Iockwire (E29).
GO TO NEXT PAGE
8-332