TM 55-2840-254-23
8-2
8-2 CLEAN MAIN OIL PUMP AND SCAVENGE OIL SCREEN (Continued)
3. Clean scavenge oil screen (2). Use dry cleaning
solvent (E17) and brush.
When using compressed air for cleaning,
use approved protective equipment for
eyes and face. Do not use more than
30 psig air pressure. Do not direct air
toward yourself or another parson.
Failure to comply could result in in-
jury to eyes or skin. In case of injury,
get medical attention.
4. Wear goggles. Blow dry screen (2) using clean,
dry compressed air.
FOLLOW-ON MAINTENANCE:
Inspect Main Oil Pump and Scavenge Oil Screen
END OF TASK