TM 55-2840-254-23
7-9
2. Remove corrosion from pin (1) of spark igniter
(2). Polish pin, using in and out motion over
entire length of pin until corrosion is removed.
Use crocus cloth (E15).
When using compressed air for cleaning,
use approved protective equipment for
eyes and face. Do not use more than
30 psig air pressure. Do not direct air
toward yourself or another person. Fail-
ure to comply could result in injury to
eyes or skin. In case of injury, get medi-
cal attention.
3. Wear goggles. Remove loosened particles from
pin (1), using clean, dry compressed air.
INSPECT
FOLLOW-ON MAINTENANCE:
END OF TASK