7-5 INSTALL IGNITION COIL AND CABLE ASSEMBLY (Continued)
7-5
3. Install spark igniter (5) on ignition lead (6).
To prevent shorting of ignition lead, do
not allow anti-seize compound to touch
4. Coat threads of ignition lead (6) with anti-seize
compound (E5).
5. Install ignition lead (6). Torque to 135 inch-
pounds. Use crowfoot attachment. Lockwire
ignition lead (6). Use Iockwire (E29).
GO TO NEXT PAGE
7-44