6-20 INSTALL LEFT- AND RIGHT-HAND FUEL MANIFOLD ASSEMBLIES (Continued)
6-20
When installing fireshield assembly, be
careful not to get five thermocouple
harness assembly leads caught between
fireshield and fourth turbine nozzle.
Failure to comply may cause damage
to harness assembly Ieads.
22. Align fireshield assembly (31) near 23 sup-
ports (9) with thermocouple jumper lead
mounting hole (32) at 5-o'clock position.
leads (33) through five cutouts (34) in fire-
shield assembly (31 ).