TM 55-2840-254-23
6-20 INSTALL LEFT- AND RIGHT-HAND FUEL MANIFOLD ASSEMBLIES (Continued)
6-20
In following step 9.,seals must be fully
seated and must be squarely against
nozzle flanges. Failure to comply will
tion, damage and leaks.
9. Install 14 seals (1) on 14 nozzles (2) on right-
hand fuel manifold assembly (16).
GO TO NEXT PAGE