6-3 CLEAN FUEL CONTROL (Continued)
2. Clean strainer element (2), ball (3), cover (4),
spring (5), retaining ring (6), and retainer (7).
Use dry cleaning solvent (E17).
When using compressed air for cleaning,
use approved proactive equipment for
eyes and face. Do not use more than
30 psig air pressure. Do not direct air
toward yourself or another person.
Failure to comply could result in in-
jury to eyes or skin. In case of injury,
get medical attention.
3. Wear goggles. Blow dry strainer element (2) us-
ing clean, dry compressed air.
FOLLOW-ON MAINTENANCE:
END OF TASK
6-15