TM 55-2840-254-23
1-111 PRESERVE AND PREPARE ENGINE FOR SHIPMENT OR STORAGE (Continued)
1-111
m. Move power lever (N1) to OFF position and
reenergize starting fuel solenoid valve (Ref.
n. Wait 10 minutes after motoring engine. This
will allow time for lubricating oil to drain into
container.
o. Remove drain hose (Appendix E) (7) from
GO TO NEXT PAGE
1-561