3-13 INSTALL COMBUSTOR CASE (AVIM) (CONT)
6.
Torque bolts (3, 4) to 47 to 53
inch-pounds according to illustrated
torquing pattern.
6.1. Allow adhesive (DO) to dry for 10
7.
8.
9.
10.
11.
12.
13.
minutes.
Torque bolts (3, 4) to
47 to 53 inch-pounds according to
illustrated torquing pattern.
Lockwire bolts with lockwire (D44).
Remove pressure sensitive tape and
residue with 1,1,1-trichloroethane
(D41).
Install gasket (6) on immersion
thermocouple (7).
Position immersion thermocouple (7)
so (CR) is facing forward and in-
stall immersion thermocouple in
combustor case.
Apply antiseize compound (D7) to
threads of bolts (8).
Install ground wire on upper side
of immersion thermocouple and se-
cure thermocouple using bolts (8),
stud (9, deleted) and nuts (10).
Torque bolts to 38 to 42 inch-
pounds.
Remove nuts (12, 13) from immersion
thermocouple connections and in-
stall marked leads (11) and nuts
(12, 13), nut (14, deleted) on
studs.
Torque nuts to 38 to 42
inch-pounds.
Change 1