2-8 INSTALL EXTERNAL LINES AND FITTINGS (Continued)
2-8
Handle tube assemblies
carefully during
installation. Tubes
are easily bent or
kinked.
Threads can
be damaged.
4.
Connect
external
lines as
follows:
a.
b.
Screw coupling nut (2) on
fitting (1) hand tight.
Hold fitting (1) with an
open end wrench and tighten
nut (2).
5.
Install clamps as
a. Install clamp
assembly.
follows:
(8) on tube
b. Secure clamp (8) to other
clamp (8) or bracket, if
used,
with screw (7), two
washers (6) and nut (5).
Tighten nut (5).
6.
Safety wire the fitting assem-
bly,
fuel drain hose and re-
strictor
fittings
with lock-
wire (E16).
INSPECT
FOLLOW-ON MAINTENANCE:
None
END OF TASK