TM 55-2835-208-23
1-20 REMOVE APU FROM REUSABLE SHIPPING CONTAINER (Continued)
1-20
2.
3.
4.
5.
6.
7.
Lift twelve latches (4) and
pull latch bolts (5) away from
container (6).
Loosen nut to
lift latch (4) if necessary.
Remove top
half of shipping
container
(6) using handles
(7).
Attach lifting
sling (T6) (8)
on APU (Task 1-21).
Hook
hoist (9) to lifting
sling (8).
Remove
and discard lockwire.
Remove captive bolts (10, 11)
that
secure
container
frame
mounting assembly (12) to APU
(13).
Remove trunnions (15).
With helper guiding APU (13),
hoist APU from container (14)
(Task 1-24).
Refer to Task 1-39 for APU in-
stallation into reusable shipp-
ing container.
8.
GO TO NEXT PAGE