2-4.
GENERAL MAINTENANCE FOR DIRECT
SUPPORT, GENERAL SUPPORT AND DEPOT. (cont)
e. Turnlock Fasteners Replacement.
(cont)
(c) Remove receptacle.
(d) Coat threads of replacement
receptacle
with threadlock compound
(MIL-S-46163) and insert in housing.
(e) Secure with retaining nut.
(f) Aline receptacle slots in
same direction as rest of receptacles.
(2) Stud replacement.
(a) Hold lockring with pliers.
(b) Close to opening in lock-
ring,
insert screw driver between
lockring and
stud and pry open.
(c) Turn stud
to allow tab
to slip past opening in lockring.
Remove stud.
(d) Insert replacement stud with
slot side to outside of access cover.
(e) Place lockring over stud.
Aline slot with tab and slide down.
NOTE
In the following
step, lockring
should be between tabs and access
cover.
(f) Pushing on top of stud
to raise
tabs,
use
pliers to
squeeze lockring closed.
(g) Release top of stud and
spring will push tabs against lockring
securing stud in place.
Figure 2-1. Turnlock Fastener