ARMY
TM 5-6115-612-34
MARINE CORPS TM 6115-34/8
AIR FORCE
TO 35C2-3-471-2
NAVY
AG-320B0-MME-000
13-8. ENGINE
OPERATIONAL
TEST.
(cont)
(7) During
start,
the turbine
(1) Stabilize oil temperature to
exhaust
temperature
exceeds
1225°F
that recorded in step f, above.
(662.8°C).
(2) Using a graduate calibrated
(8) Speed exceeds 110 percent.
in
cubic
centimeters,
measure
that
amount of oil required to bring oil
(9) After the first successful
level to FULL mark on dipstick. Divide
start, starting is delayed or erratic.
quantity of oil used by elapsed time of
run in hours (cc/elapsed time hours).
(10) Unusual/abnormal noises.
j. Perform tests (1) through (9) in 13-9. GENERATOR
SET
OPERATIONAL
table 13-1.
TEST .
After receiving a successfully
tested
engine,
install
engine in
k. Compute
oil
consumption
fol-
generator set and test in accordance
lowing steps 9 and 13, table 13-1, as
with table 13-4.
See figure 13-6 for
follows:
the control panel layout.
13-13